Pump Technology Catalogue 2019

3 2 56 Youngs Industrial Estate, Aldermaston, Berks. RG7 4PW Tel: 0118 9821555 Fax: 0118 9821666 E-mail: support@pumptechnology.co.uk Web Site: www.pumptechnology.co.uk CHARCOVENT & MICROVENT Carbon/Charcoal Filter-Breather Systems for venting Pump Technology Ltd. Waste Water and Sewage Pumping Systems where a vent to atmosphere is not possible (all pumping systems require a vent). Both CHARCOVENT and MICROVENT contain an Activated Carbon Filter with highly absorptive powers ideal for removing unpleasant odours and gaseous contaminates from an air stream and also allow two way air passage to enable the pump unit to breathe. NOTE: CHARCOVENT and MICROVENT should be fitted at the same height or higher than the highest point of the discharge pipework. Where possible vent unit into Ceiling Void, or similar. The CHARCOVENT should be fitted to tank using 1¼" pipework and a tank connector positioned through the side of the tank NOT THE LID -as high as possible from the base of the unit. CHARCOVENT For Waste Water Pumping Systems WITHOUT VERY HOT WATER MICROVENT For Waste Water (VERY HOT) and Sewage Pumping Systems MICROVENT should be used with: a) Waste Water Pumping Systems where waste water is EXTREMELY HOT i.e Commercial Dishwashers, Glasswashers etc. (connect to minimum 2" pipework) b) With Floor Mounted Sewage Pumping Systems e.g. EFFLU MIDI, EFFLU MACRO & EFFLU MAXI (connect to minimum 3" pipework) BSP 1¼'' THREAD The SOLUTION when it is not possible to “Vent to Air” MICROVENT FITTED TO EFFLU MAXI