Pump Technology Catalogue 2019

28 56 Youngs Industrial Estate, Aldermaston, Berks. RG7 4PW Tel: 0118 9821555 Fax: 0118 9821666 E-mail: support@pumptechnology.co.uk Web Site: www.pumptechnology.co.uk Pump Technology Ltd can supply any control panel to meet the customers specification. We can offer single to multiple pump controls, GSM or landline telemetry, ATEX rated, battery backup and hour run meters. Reliable and cost-effective control system for the arduous and turbulent conditions encountered in COMMERCIAL APPLICATIONS. z Simple installation from outside of sump z Easy visibility of start and stop points z Unaffected by fat, grease, debris and foam z Excellent in turbulent sumps z Safe, low sensing voltage CONTROL PANELS EXAMPLE OF A DUAL PUMP CONTROL PANEL OPERATION SYSTEM OPERATION The system controls the level into the storage tank automatically via the non-mercury operated float switches. Assist Start Float is set to the level at which the second pump is required to start. High Level Float is set to the level at which the alarm is required to give warnings of potential flood conditions. This should be set at the level of the INLET to maximise the tank capacity. Duty Start Float is set to the level at which the first pump is required to start. Stop Float is set to the level at which the pumps are required to stop. This must be set above the volute of the pump.